Bioactivity | Mito-Rh-S is a ratiometric near-infrared (NIR) fluorescent probe that detects the fluctuation of mitochondrial HClO levels during ferroptosis in hepatocellular carcinoma (HCC)[1]. |
Invitro | Mito-Rh-S 具有超快的响应速度(2s)和大的发射位移(115 nm)。Mito-Rh-S 具有高信噪比[1]。Mito-Rh-S 的细胞实验表明,HepG2 细胞中 Fe2+ 和 Erastin (HY-15763) 诱导的铁死亡导致线粒体 HClO 水平升高[1]。 MCE has not independently confirmed the accuracy of these methods. They are for reference only. 0 --> Mito-Rh-S 相关抗体: |
Formula | C40H39ClN2O5S |
Molar Mass | 695.27 |
Transport | Room temperature in continental US; may vary elsewhere. |
Storage | Please store the product under the recommended conditions in the Certificate of Analysis. |
Reference | [1]. Bo Zhao, et al. Ratiometric Near-Infrared Fluorescent Probe Monitors Ferroptosis in HCC Cells by Imaging HClO in Mitochondria. Anal Chem. 2024 Apr 16;96(15):5992-6000. |